Product Name: SMART GRID &PHOTOVOLTAIC ENERGY TRAINER
Model Name: YESRE-SGPET
Features
·Open circuit voltage Voc and short circuit current Isc characteristics practice·Practice of measuring changes in current and voltage according to hatching changes at a certain amount of light ·Practice of measuring open circuit voltage Voc and short circuit current Isc of solar modules ·Practice of measuring changes in current and voltage according to hatching changes at a certain amount of light
Specification
01. AC POWER SOURCE A) Size : 210(W) x 296(H) x 100(D)mm B) MCCB (AC220V/60Hz/20A) : 1EA C) AC Power Indicator : 1EA D) AC Inlet (Built-in fuse) / AC Outlet: 1EA each E) 1KW Dimmer for halogen lighting : 1EA 02. PHOTOVOLTAIC CELL MODULE A) Size : 420(W) x 296(H) x 200(D)mm B) PV Module -Max. Power: Pm: 5W -Max. Power Voltage: Vmp: 17.5V -Max. Power Current: Imp: 300mA -Open - Circuit Voltage: Voc: 21.4V -Short - Circuit Current: Isc: 390mA C) DC Voltage Meter/ DC Current Meter: 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each D) PV output terminal (4mm insulated type): 1 set each E) Solar panel temperature display module: 1EA F) Connector (RS485 communication): 2EA 03. PHOTOVOLTAIC CELL MODULE-2 A) Size : 420(W) x 296(H) x 100(D)mm B) PV Module: 6EA -Max. Power: Pm: 0.5W -Max. Power Voltage: Vmp: 3V -Max. Power Current: Imp: 170mA -Open - Circuit Voltage: Voc: 3.6V -Short - Circuit Current: Isc: 18mA C) DC Voltage Meter/ DC Current Meter: 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each D) PV output terminal (4mm insulated type): 6 sets each F) Connector (RS485 communication): 2EA 04. BATTERY MODULE A) Size : 420(W) x 296(H) x 130(D)mm B) Battery(12V, 7AH) : 2EA C) Battery output terminal (4mm insulated type): 1 set each D) DC Voltage Meter: 1EA -Maximum measurement input specification: DC500V -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each E) Fuse Holder (15A): 2EA F) Connector (RS485 communication): 2EA G) AC Inlet/ AC Outlet: 1EA each 05. STAND-ALONE INVERTER MODULE] A) Size : 420(W) x 296(H) x 100(D)mm B) Inverter -Output(AC) : 400W -Frequency: 60Hz -Input (DC): Low voltage (10.5±0.3V warning / 10V±0.3V automatic shutdown) High voltage (auto shutdown when 16.5V or higher) -Protection function: overheat, short circuit, overload -Warning function: Beep sound when an error occurs C) DC Voltage Meter/ DC Ampere Meter : 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each D) AC Voltage Meter/ AC Ampere Meter: 1EA each -Maximum measurement input specification: AC500V, AC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -AC frequency measurement function (measurement range: 0.1 to 9999Hz) -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each E) Inverter Main Switch: 1EA F) DC input terminal (10.5V~16.5V 4mm insulated type): 1 set G) AC output terminal (4mm insulated type): 2 sets H) Connector (RS485 communication): 2EA G) AC Inlet/ AC Outlet: 1EA each 06. HYBRID CHARGER MODULE A) Size : 420(W) x 296(H) x 100(D)mm B) Charging Controller -System voltage: 12V -Maximum input voltage: 25V -Rated input current: 6A -Rated output current: 6A -PV short circuit current: 9A -Battery Low Voltage Disconnect (LVD): 11.3V -Battery low voltage return: 12.5V -Temperature compensation: -4mV/Cell*k C) DC Voltage Meter/ DC Ampere Meter : 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each D) PV / Wind / Etc input terminals (4mm insulated type): 1 set each E) Battery connection terminal (4mm insulated type): 1 set F) Output terminal for load (4mm insulated type): 2 sets G) Input and output status indication LED: 1EA each H) Connector (RS485 communication): 2EA I) AC Inlet/ AC Outlet: 1EA each 07. DC LOAD MODULE A) Size : 420(W) x 296(H) x 100(D)mm B) DC LOAD-1 –50W class halogen lamp: 1EA -Rated voltage: DC12V -Connecting terminal (4mm insulated type): 1 set -On/Off switch : 1EA C) DC LOAD-1 -5W class DC motor : 1EA -Rated voltage: DC12V -Attachment of rotating plate for easy identification of rotating state -Connecting terminal (4mm insulated type): 1 set -On/Off switch : 1EA D) Variable resistor for 50W class load: 1EA E) DC Voltage Meter/ DC Ampere Meter : 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each F) Connector (RS485 communication): 2EA G) AC Inlet/ AC Outlet: 1EA each 08. AC LOAD MODULE A) Size : 420(W) x 296(H) x 100(D)mm B) AC LOAD-1 –4W class fluorescent lamp: 1EA -Rated voltage: AC220V -Connecting terminal (4mm insulated type): 1 set -On/Off switch : 1EA C) AC LOAD-1 -5W class AC synchronous motor: 1EA -Rated voltage: AC220V -Attachment of rotating plate for easy identification of rotating state -Connecting terminal (4mm insulated type): 1 set -On/Off switch : 1EA D) Built-in 2-prong AC Outlet: 1EA E) AC Voltage Meter/ AC Ampere Meter: 1EA each -Maximum measurement input specification: AC500V, AC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -AC frequency measurement function (measurement range: 0.1 to 9999Hz) -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each F) Connector (RS485 communication): 2EA G) AC Inlet/ AC Outlet: 1EA each 09. VIRTUAL PHOTOVOLTAIC CELL MODULE A) Size : 450(W) x 296(H) x 250(D)mm B) Built-in 1KW class lottery transformer for insulation C) Built-in 1KW class slidex for voltage control D) Built-in Max 100A rectifier circuit E) Maximum output voltage: 60VDC F) Built-in lamp for checking output G) V-PV output terminal (4mm insulated type): 1 set H) AC Inlet/ AC Outlet: 1EA each 10. GRID TIED INVERTER MODULE A) Size : 450(W) x 296(H) x 250(D)mm B) Grid-connected inverter -AC Max Power: 600W -Maximum solar input voltage: 22~60VDC -MPPT voltage range: 25~48V -Max DC current: 30A -Input control method: MPPT control -Output Rated Capacity: 500W -Output rated voltage: 190~260Vac -Output frequency: 50/60Hz -Output control method: PWM -Output power factor: 98% or more C) Import Watt-Hour Meter/Export Watt-Hour Meter: 1EA each -Phase/wire type: single-phase 2-wire type -Rated voltage: AC 220V -Rated current: 40A -Rated frequency: 60Hz -Instrument constant: 1.0Wh/Pulse -Applicable standard: IEC 62053-21, IEC-62053-11, KS C 1214 D) DC MCCB (2 poles, DC 120V/15A) : 1EA E) AC MCCB (AC220V/60Hz/15A) : 2EA F) DC input terminal (4mm insulated type): 1 set G) AC output terminal (4mm insulated type): 1 set H) Connector (RS485 communication): 2EA C) AC Outlet : 1EA T) Ground connection terminal (4mm insulated type): 1EA 11. WIND GENERATOR MODULE A) Size : 450(W) x 300(H) x 450(D)mm B) Wind generator -Rated voltage : 8.21V -Current rating ; 3.83A -Rated speed : 523 rpm/min -Output terminal (4mm insulated type): 1 set C) DC Voltage Meter/ DC Ampere Meter : 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each D) Connector (RS485 communication): 2EA E) AC Inlet/ AC Outlet: 1EA each 12. FUEL CELL MODULE A) Reversible PEM fuel cell method B) Built-in battery for electrolysis C) Built-in DC motor for load D) DC Voltage Meter/ DC Ampere Meter: 1EA each -Maximum measurement input specification: DC500V, DC5A -Maximum display range: -1999 ~ 9999 -Highly functionalized Hi/Low scale function of display -Communication function: RS485 -Voltage/current input terminals (4mm insulated type): 1 set each E) Connector (RS485 communication): 2EA F) AC Inlet/ AC Outlet: 1EA each 13. SMART GRID MONITOR MODULE B) Instrument monitoring using RS-485 communication C) Possible to connect to PC using USB E) Solar power generation experimental device PC S/W - Check voltage/current data by module (text and graph) - Graph and data saving function in Excel - PV module I-V, P-V characteristic test possible - Solar cell voltage/current/power, inverter voltage/current display possible F) Connector (RS485 communication): 1EA G) AC Inlet/ AC Outlet: 1EA each 14. Dedicated practice table for solar power generation experiment equipment A) SIZE : 1800(W)×1392(H)×320(D)mm B) 300W class halogen lamp mounting type structure capable of testing the incident angle of sunlight C) Material: MDF, drawer, lockable |